When using the solar module laminator, some problems may occur. The following lists possible faults and elimination method
|
NO. |
Fault phenomenon |
Possible reason |
Elimination method |
|
1 |
After the upper cover is closed, the upper or lower chamber cannot be vacuumed. |
Vacuum pump does not work |
Make the vacuum pump work properly |
|
The rotation direction of the vacuum pump is inconsistent with the direction marked on the pump body arrow |
Change the wiring phase sequence so that the rotation direction of the vacuum pump is consistent with the arrow |
||
|
Compressed air pressure is not normal |
Adjust compressed air pressure |
||
|
The open/close cover limit switch does not work properly. |
Adjust or replace the limit switch |
||
|
2 |
After the cover is closed, the lower chamber can be vacuumed, and the upper chamber cannot be vacuumed. |
Upper chamber pipeline air leakage |
Find the leakage point and repair |
|
Upper chamber vacuum solenoid valve can not start |
Make the compressed air pressure meet the requirements or replace the solenoid valve |
||
|
Upper chamber inflation and vacuum switch damage |
Replace switch |
||
|
3 |
The upper chamber cannot be vacuumed after opening the upper cover |
Upper chamber pipeline air leakage |
Find the leakage point and repair |
|
Upper chamber vacuum solenoid valve can not start |
Make the compressed air pressure meet the requirements or replace the solenoid valve |
||
|
Upper chamber inflation and vacuum switch damage |
Replace switch |
||
|
Silica gel plate damage |
Replace the silica gel plate |
||
|
Pressing strip frame screws are not tightened |
Retighten the screws |
||
|
Lower chamber vacuum valve is not working properly |
Adjust compressed air pressure or replace vacuum valve |
||
|
Lower chamber inflation solenoid valve loosen and leaks air. |
Retighten or replace the lower chamber inflation solenoid valve |
||
|
4 |
The upper chamber cannot be inflated |
Upper chamber inflation solenoid valve can not start |
Check the line or replace the upper chamber inflation solenoid valve |
|
The upper chamber vacuum valve can not be properly started or tightly closed. |
Repair or replace the valve |
||
|
5 |
The upper chamber can be inflated, while the upper chamber vacuum gauge pointer cannot return to zero |
Vacuum gauge damage |
Replace |
|
The plastic tube connected to the vacuum gauge has a dead bend |
Straighten out |
||
|
The upper chamber vacuum valve is not closed tightly |
Close tightly or replace |
||
|
6 |
The lower chamber cannot be inflated |
The lower chamber inflation solenoid valve is damaged and cannot be started. |
Replace |
|
Lower chamber inflation switch/lower chamber vacuum switch is damaged |
Replace switch |
||
|
7 |
The lower chamber can be inflated, while the lower chamber vacuum gauge pointer cannot return to zero |
The lower chamber vacuum valve is not closed tightly |
Adjust the lower chamber vacuum valve |
|
8 |
In the vacuum state of the upper and lower chambers, while the upper chamber is inflated, the pressure in the lower chamber is simultaneously reduced. |
Silica gel plate damage |
Replace the Silica gel plate |
|
9 |
In the vacuum state of the upper and lower chambers, the pressure in the upper chamber is simultaneously reduced while the lower chamber is inflated. |
Silica gel plate damage |
Replace the Silica gel plate |
|
The lower chamber vacuum valve is not closed tightly |
Adjust the lower chamber vacuum valve |
||
|
10 |
Low vacuum degree |
Seal ring joint split |
Reconnect |
|
Excessive impurities in vacuum pump oil |
Replace the vacuum pump oil |
||
|
Lower chamber vacuum valve leaks air |
Replace or repair |
||
|
The fixing screw of the vacuum pump elbow is loose |
Tighten the screws |
||
|
Vacuum pump belt is too loose |
Adjust belt tightness |
To know more information,please contact us.