When using the solar module laminator, some problems may occur. The following lists possible faults and elimination method:
NO. | Fault phenomenon | Possible reason | Elimination method |
1 | The cover cannot be opened | The compressed air pressure of the air compressor is abnormal | Adjust compressed air pressure |
The connection pipe of the cylinder is leaking air | Check the pipeline to troubleshoot | ||
Open cover solenoid valve is damaged | replace | ||
The lower chamber is under vacuum state | Inflating the lower chamber | ||
2 | The sequence occurs chaos in the automatic running state | The connection line of the PLC is loose or there is a problem with the program. | Tighten the fixing wire screw on the PLC or refresh the program |
3 | Vacuum degree reduced during lamination | Silica gel plate damage | Replace the Silica gel plate |
The upper chamber vacuum valve is not closed tightly, and the silica gel plate screws are loose. | Repair or replace, tighten the screws | ||
4 | Low vacuum degree while the lower chamber is vacuuming | Sealing strip joint split | Repair or replace |
Upper chamber inflation/lower chamber inflation solenoid valve joint is loose | Remove and add 704 glue then tighten | ||
Vacuum pump oil is too little | Add vacuum pump oil | ||
Vacuum pump belt is too loose | Adjust the belt tightness | ||
The fixing screws are loose between the vacuum pump and elbow | Tighten | ||
The seal ring of vacuum valve of Lower chamber needs to be replaced | Replace the seal ring | ||
Metal gauge tube of vacuum gauge or vacuum gauge head is damaged | Replace the vacuum gauge | ||
The connecting pipe between the vacuum pump and the laminator is not tightly inserted. | Tightly re-insert the connecting pipe | ||
Solenoid valve is damaged | Replace | ||
The power supply voltage is abnormal. | Check the supply voltage | ||
Electromagnetic inflation valve is not open | Check circuit | ||
5 | Roots pump tripping | Electric circuit failure | Check electric circuit |
Motor failure | Detect the motor and see if there is any problem with no-load | ||
Sundries enters the Roots pump | Look at the air inlet and exhaust | ||
The vacuum degree is reduced and causing the Roots pump to overload | Run the vacuum pump separately to see if the vacuum degree is enough | ||
Roots pump starts too early | Check the Roots pump start setting value | ||
Roots pump failure | Listen to noise and dismantle to check. | ||
6 | Temperature display error | The wire of platinum resistance disconnected | Replace platinum resistance |
Temperature module is damaged | Recommended to replace the module | ||
Abnormal communication | Re-plugging the communication cable | ||
7 | Class A cannot be fed | Check whether there is a signal for the module arrival photoelectric switch of Stage A. | Check the Stage A module arrival photoelectric |
Whether there is a open cover in place signal | Open the cover in place or check the In place switch | ||
Check whether there is a signal for Stage C stop photoelectric | Check the Stage C stop photoelectric | ||
8 | The set temperature deviates too much from the actual temperature | Thermocouple damaged | Replace |
9 | The vacuum pump has been emitting white smoke during operation | The circulating water is abnormal or did not open | Check and make it normal |
Vacuum pump oil is too little or too dirty | Add or replace | ||
Vacuum pipe is not tightly sealed | Check and seal with silicone | ||
10 | The vacuum degree of the vacuum gauge does not match the set vacuum degree | Vacuum valve pumping too fast or too slow | Check and repair |
Vacuum gauge display is abnormal | Debug or replace the gauge | ||
Vacuum pump is abnormal | Repair it | ||
11 | The vacuum degree displayed on the touch screen is inconsistent with the vacuum degree displayed on the vacuum gauge | Vacuum gauge displays abnormally | Replace |
Vacuum pump is abnormal | Repair it | ||
Incorrect parameter settings | Reset parameters | ||
12 | Solenoid valve and controller are unstable during automatic or manual operation status | Screws for fixing the line are loose | Check and tighten |
Solenoid valve is damaged | Replace | ||
The power supply voltage is abnormal. | Check the power supply voltage |