Daily check of solar module laminator

Oct 28, 2024

(1)Check whether the air source is stable and abnormal, and whether the air pressure is within the range value (0.4 to 0.8 MPa);
(2)Check if the emergency stop button is reliable;
(3)Check whether the opening and closing cover is normal, and there must be no large swing or abnormal noise;
(4)Check if the each sensor is normal;
(5)Check and ensure that the vacuum pump oil is within the specified range;
(6)Check whether the connections of the various parts of the device are normal;
(7)Check the sealing strip on the top cover of the main unit to clean, no residue, no serious wear and aging;
(8)Check the cover Silica gel plate on the main unit, no damage, wrinkles, no residual EVA or accumulated dust;
(9)Check for no residual EVA and accumulated dust on the heating table and glass transfer cloth;
(10)Check that the vacuum pump is working properly, without severe vibration and abnormal noise;
(11)Check if the vacuum in the upper chamber is normal;
(12)Check if the vacuum in the lower chamber is normal;
(13)Check the temperature measurement point abnormality and temperature uniformity.