1. The vacuum degree cannot be raised or drops rapidly

A. Possible reasons

a. Insufficient or deteriorated vacuum pump oil

b. Vacuum pipeline leakage

c. The sealing ring is aged or damaged

d. The vacuum valve is not fully opened or malfunctions

B. Treatment Method

a. Check and replace the vacuum pump oil

b. Check for leaks with soapy water and tighten

c. Replace the sealing ring

d. Check the valves and control circuits

2. Unstable lamination temperature

A. Possible reasons

a. The thermocouple is damaged or has poor contact

b. Solid-state relay (SSR) or contactor failure

c. The heating tube is damaged

B. Treatment Method

a. Inspect or replace the thermocouple

b. Check and replace the SSR/ contactor

c. Measure the resistance of the heating tube with a multimeter and replace the damaged part